Recalls in Canada
1 Transport Canada recall for the 2022 Prevost X3-45 VIP.
| 2022191 14 Apr 2022 | Engine Issue: On certain vehicles, if the front bearing on the alternator fails, the alternator belts could continue to turn the alternator. This could cause the alt… |
Transport Canada Vehicle Recalls Database · Contains information licensed under the Open Government Licence – Canada
Recalls
Prevost Car (US) Inc. (Prevost) is recalling certain 2010-2023 H3-45, H3-45 VIP, X3-45, X3-45 Com, and X3-45 VIP vehicles. In the event of the alternator front bearing seizing, the alternator belt may continue to operate, causing the bearing to overheat.
Whether a recall was fixed on a particular car is known only to the manufacturer: check the VIN at nhtsa.gov/recalls.
NHTSA recalls · summaries in NHTSA's own words
Service bulletins
What Prevost told its dealers about the 2022 Prevost X3-45 VIP: known faults, fixes and updates.
| Bulletin | Summary |
|---|---|
| 11003159 | Sway bar collars improvement. Revision A : Add front sway bar support replacement and change bolts lenght. |
| 10248275 | SWAY BAR COLLARS IMPROVEMENT |
| 10238423 | Window Gaps Minimum Clearance on Converted Shells |
| 10233625 | On the vehicles affected by this bulletin, the Vehicle Emission Control Information label must be replaced. Revision: B - Causal part changed, was 010352, becomes 85152363. No impact on procedure or parts involved. |
| 10233622 | Prevost Driver Assist System Description. Revision A - EFFECTIVE ON H3-45 SERIES UP TO VEHICLE P-1452 |
| 10231093 | STEERING GATEWAY. Revision B - PIN 2 and 10 were inverted on connector A139 |
| 10228667 | Air Tanks Draining Sequence. Revision: B - General Update |
| 10226928 | Air Tanks Draining Sequence. Revision: A - Erroneous Secondary & Accessory tanks location. |
| 10226927 | Air Tanks Draining Sequence |
| 10222380 | TAG AXLE HUB FLANGE - ALTERNATE CAP SCREW |
| 10219023 | STEERING GATEWAY, revision A : Cancel watch dog removal from EFD part of the instruction |
| 10217314 | STORAGE AND STARTUP GUIDELINES : part number updates |
| 10217311 | TGW PROGRAMMING |
| 10214937 | X3 SERIES ENVIROCARE - IONS AIR SANITIZER |
| 10214936 | STEERING GATEWAY Revision A Cancel watch dog removal from EFD part of the instruction |
| 10214935 | CENTRAL HVAC MERV FILTERS INSTALLATION |
| 10213318 | BRAKE PEDAL SEAL PLATE INSTALLATION KIT |
| 10213317 | STEERING GATEWAY schematic |
| 10209744 | Surge tank pressure cap replacement |
| 10205938 | An automated test is available to check the big HVAC superheat from the driver seat. This test is controlled by Multiplex, eliminating interventions and the need to take measures on the vehicle. |
| 10201835 | RONT & TAG AXLE UNITIZED HUB BEARING END PLAY VERIFICATION AND REPLACEMENT |
| 10199007 | STORAGE AND STARTUP GUIDELINES: Periodically, circumstances arise requiring operators to temporarily park a coach in storage. Whether it is a few weeks or several months, sporadic out of service times or a full stop, Prevost recommends following the guidelines in this document during times when: The coach can be operated on a regular/weekly basis while in storage. The coach will be in storage for an extended period without any operation. The coach will return to service following an extended period of downtime. |
| 10199002 | CENTRAL HVAC MERV FILTERS INSTALLATION REVA |
| 10186398 | Rev A: Mention added concerning DDC Series 60 engine SCA requirement |
| 10186373 | VOLVO I-SHIFT TRANSMISSION REPLACEMENT - DIFFERENCE BETWEEN CONNECTIONS AT THE TOP OF THE OIL FILTER HOUSING |
NHTSA manufacturer communications (public domain)
NHTSA investigations
Alternator Front Bearing Failure
NHTSA Office of Defects Investigation