The issue
On certain 3-way refrigerators (propane AC and DC), a low cycle fatigue failure could occur in the section of the cooling unit which generates the refrigerant. This occurs due to elevated heat when the refrigerator is operated in the AC power mode. This fracture can cause the liquid solution to leak from the cooling unit and can result in the generation of very high temperatures. This can in turn cause the steel material to soften and rupture and if the pressurizing hydrogen gas is still in place when the rupture occurs, the gas may be expelled and possibly be ignited by the high temperature causing a fire. Correction: A new cooling unit will be installed.
Description (français)
Sur certains réfrigérateurs trifonctionnels (propane, c.a. et c.c.) modèles N841, N821, N641 et N621, à cause de la chaleur excessive qui se dégage quand le réfrigérateur fonctionne en mode c.a., une défaillance par fatigue oligocyclique peut survenir dans la section du système de réfrigération qui produit le frigorigène Cette défaillance peut entraîner une fuite de réfrigérant qui peut se traduire par un dégagement de températures très élevées. Il se peut alors que les pièces métalliques s'amollissent et se rompent et, si l'hydrogène de pressurisation est encore en place quand la rupture survient, qu'il se produise une fuite de gaz qui peut s'enflammer à cause des températures élevées en présence. Correction: Un nouveau système de réfrigération va être installé.
Transport Canada Vehicle Recalls Database · Contains information licensed under the Open Government Licence – Canada · official text, unchanged
Vehicles covered
| Make and model | Model years |
|---|---|
| Norcold N621 | 1999 |
| Norcold N641 | 1999 |
| Norcold N821 | 1999 |
| Norcold N841 | 1999 |